Controls |
Controls arranged to resemble the physical appearance of the device. Note: The mixer controls are designed to be wired to a DSP mixer device, as by default they will not actually perform any function. |
Raw Controls |
Controls from the Controls tab arranged in a simple format with LEDs next to each of the main buttons. |
Comms (serial) |
|
Comm port |
The RS-232 COM port of the device (a NioNode, for example) directly connected to the JL Cooper device. For the NioNode RS-232 port, specify For the nControl node, specify |
Rear Port |
The RS-422 / RS-485 COM port of the device (an nControl node, for example) directly connected to the JL Cooper device. For the nControl node, specify Note: A connection to a JL Cooper device via the RS-422/RS-485 port at the rear of an nControl node has not been tested with the current release of software and hardware. |
Status |
Status message showing whether the device responded. |
Connected |
Lit (green) when a connection has been made to the device. |
Comms (TCP) |
|
IP address |
The IP address of the device you want to contact. This value can be edited. |
IP port |
The port number on which the device will listen for data transmissions from other devices. This setting must match the port number used by the transmitting device. The default is 0. The valid range is 0-65535. |
Status |
Status message showing whether the device responded. |
Connected |
Lit (green) when a connection has been made to the device. |
|
See also |